In ductus CO2 et T/RH transmitter

Description:

Real tempus dioxide deprehensio in aere duct
Princeps accurate temperatus et humiditas relativa
cum extendable aeris specillum in aerem ductus
Instructus aqua probatione et velo rariori circa sensorem probe
Ad III Analog lineares outputs in III mensuras superiores
Modbus RS485 interface pro 4 mensuris
Cum aut sine LCD propono
CE-approbatio

Duct CO2 Transmitter, CO2 Detector, Air Quality Detector, CO2 Metre In Air Duct, TG9 Co2 Transmiiter, CO2 Transmitter, CO2 Temperature Umor Transmitter, Carbon Dioxide Monitor, CO2 Monitor, IAQ Detector, CO2 Duct Sensor, Duct CO2 Sensor, CO2 VOC Detector, CO2 et TVOC Transmitter, Air Quality Meter, Carbon Dioxide Meter, Carbon Dioxide Transmitter, CO2 Plus VOC Meter, Carbon Dioxide Detector, Carbon Dioxide Sensor, Duct Air Quality Sensor, Duct Adscendens, CO2 Sensor, CO2 Plus VOC Transmitter, CO2 Transmitter in Duct Adscendens, Externi CO2 Sensor


Breves

Product Tags

FEATURES

Real tempus dioxide deprehensio in aere duct
Princeps accurate temperatus et humiditas relativa
cum extendable aeris specillum in aerem ductus
Instructus aqua probatione et velo rariori circa sensorem probe
Ad III Analog lineares outputs in III mensuras superiores
Modbus RS485 interface pro 4 mensuris
Cum aut sine LCD propono
CE-approbatio

 

CUBITS TECHNICAL

Cras parametri

CO2

Temperature

Relativum humiditas
Sensus elementum Infrared Detector Non Dispersive (NDIR) Digital combined temperatura et humiditas sensoris
range mensuræ

0~2000ppm(default) 0~5000ppm

(Selectable in ordinem)

0℃~50℃(32℉~122℉) (default) 0~100% RH
Propono Consilium

1ppm

0.1℃

0.1% RH
Cura@25(77) ± 60ppm + 3% lectionis

±0.5℃ (0℃~50℃)

±3%RH (20%-80%RH)

Vita

XV annis (normalis)

X annis

Exolvuntur calibratiis ABC Logic Self Calibration

--

--

Responsio tempus <II minuta ad XC% mutatio <X seconds ad LXIII%
RECALFACIO tempore II horas (primum) II minuta (operatio)

Characteres electrici

Potentia copia 24VAC/VDC
Consummatio 3.5 W max.;2.5 W AVG.

Outputs

Duabus aut tribus analog outputs0~ 10VDC (default) vel 4~ 20mA (selectable by jumpers) 0~5VDC (delecti ad locum ordinem)
Modbus RS485 interface (optional) back RS-485 cum protocollo Modbus, 19200bps rate, 15KV praesidium antistatic, basis independens electronica

Condiciones utendi et instruendi

Operatio conditionibus 0~50(32~ 122);0~95%RH, non condensing
Repono conditionibus 0~50℃(32~122℉)/ 5~80% RH

Pondus

320g
Institutionem Certa in aere duct cum 100mm institutionem foraminis magnitudine
 Genus habitationi IP IP50 pro nullo LCD IP40 quia cum LCD
Standard CE-Approbatio

  • Priora:
  • Deinde: