CO2 Sensor in Temperature et Umore optionis

Brevis descriptio:

Designed for real-time monitoring of environmental CO2 concentrations and temperature and humidity .
Co2 sensorem aedificavit in NDIR infrared. Munus sui tenendo;
Fac CO2 vigilantiam veriorem et firmiorem
CO2 modulus 10year vitam excedit
Magna cura temperatura et humiditas magna, transmissio ad libitum
Usus caloris digitalis et humiditatis sensoriis, perfecta effectione caliditatis
Compensatio functionis humiditatis ad mensurationem CO2
Ter color backlit LCD praebet munus intuitive monitionem
Varietas murus ascendens dimensiones faciles usui praesto sunt
Provide Modbus RS485 communicationis interface optiones
24VAC/VDC potestas copia
EU vexillum, CE certificationem


  • :
  • Brevis Introductio

    Product Tags

    FEATURES

    Design pro reali tempus mensurans ambiance dioxide graduum et temperatus +RH%
    NDIR CO2 sensorem intus infrarubrum cum peculiari sui Calibratione. Mensurationem CO2 veriorem et certiorem facit.
    Plus quam X annos in vita CO2 sensorem
    Princeps accurate temperatus et humiditas mensurae
    Composita et humiditas et temperatus sensoriis seamlessly digitalis auto- recompensationis
    Analog tria ad mensurae outputs linearibus providere
    LCD libitum est ostendere CO2 et temperatus & RH mensuras
    Modbus communicationis libitum
    24VAC/VDC potestas copia
    EU vexillum et CE approbatione

    ARTI SPECIFICATIONIS

    Carbon Dioxide
    Sensus elementum Non dispersiva infrared Detector (NDIR)
    CO2 range mensuræ 0 ~ 2000ppm/ 0~5,000ppm, 10000ppm et 50000ppm libitum est
    CO2 Cura @22℃(72℉) ± 40ppm + 3% lectionis vel ± 75ppm (utrumlibet maius)
    Temperatus dependentia 0.2% FS per℃
    Stabilitas <2% FS super vita sensoris (anno XV typicam)
    Pressura dependentia 0,13% legendi per mm Hg *
    Calibration ABC Logic Self Calibration Algorithmus
    Responsum tempus <II minuta ad XC% gradum mutatio typical
    Signum renovatio Omnis II seconds
    Fermentum tempus II horas (primum tempus) / II minuta (operatio)
    Temperature

    Umor

    range mensuræ 0℃~50℃(32℉~122℉) (default) 0 ~100% RH
    Sagacitas ±0.4℃ (20℃~40℃) ±3%RH (20%-80%RH)
    Propono resolutio 0.1℃ 0.1% RH
    Stabilitas <0.04℃/anno <0.5%RH/annus
    Generalis Data
    Potentia copia 24VAC/VDC
    Consummatio 1.8 W max. ; 1.2 W AVG.
     Analog outputs 1~3 X analog outputs0~ 10VDC (default) vel 4~ 20mA (selectable by jumpers) 0~5VDC (delecti ad ordinem collocandi)
    Modbus communicationis (libitum) RS-485 cum Modbus protocollo, 19200bps rate, 15KV antistaticprotection, independens basis inscriptionis.
    Operatio conditionibus 0~50(32~ 122); 0~95%RH, non condensing
    Repono conditionibus 10~50℃(50~122), 20~60% RH non condensans
    Net Pondus 240g
    Dimensiones 130mm(H)×85mm(W)×36.5mm(D)
    Institutionem murus ascendens cum 65mm×65mm seu II "-4" filum buxum
    Habitationem et IP classis PC/ABS fireproof materia plastica, tutela classis: IP30
    Standard CE-Approbatio